XScopes User’s Manual 2.3 Trigger Settings The XScope has an advance triggering system, it has most of the trigger controls of a professional oscilloscope. 2.2.2 Channel Gain Table 5 shows the possible gain settings for the analog channels. Figure 19: Vertical menus 2.2.1 Disable Channel Any channel can be disabled this is useful to reduce clutter on the display. XScopes User’s Manual 2.2 Vertical Settings The analog channel controls are discussed in this section. Table 4 shows all the possible time bases. 2.1.1 Time Base The time base can be varied from 8µs/div to 50s/div. 2.1 Horizontal Settings The horizontal settings are controlled on the default menu. More information about the digital channels is presented in chapter 3. This chapter will focus on the analog signals. Mixed Signal Oscilloscope The XScope is a mixed signal oscilloscope it has 2 analog channels and 8 digital channels. Further ramifications are shown on the respective chapters. ![]() ![]() Figure 17 shows the main menus in blue and some secondary menus in yellow. When the MENU button is pressed on the last menu, the device settings are saved and the menu goes back to the default. The green arrows represent the flow when pressing the MENU button. The K1 - K3 buttons action depend on the current menu. XScopes User’s Manual 1.8 User Interface The K4 button is the MENU button, used to navigate thru all the menus. The maximum voltage on the analog inputs has only been tested to these limits. XScopes User’s Manual 1.5 Absolute Maximum Ratings Parameter Supply Voltage (+5V) Analog Inputs1 Digital Inputs External Trigger Operating Temperature Storage Temperature Xprotolab & Xminilab Minimum Maximum -0.5 5.5 -30 30 -0.5 3.8 -3.5 6.8 -40 70 -40 80 Portable Variants Minimum Maximum N/A (Battery Powered) -180 180 -0.5 5.5 -3.5 6.8 -40 70 -40 80 Unit V V V V ☌ ☌ Table 3: Absolute Maximum Ratings 1. XScopes User’s Manual 1.4 Dimensions Figure 11: Xprotolab Dimensions Figure 12: Xminilab 2.1 & 2.2 Dimensions Figure 13: Xminilab 2.3 Dimensions Figure 14: Xprotolab-Portable Dimensions Figure 15: Xminilab-Portable Dimensions DS-XScopes-3. Sampling rate Analog Bandwidth Resolution Input Impedance Buffer size Input Voltage Range Vertical Sensitivity Analog Outputs Max. Sampling rate Buffer Size Frequency Counter Sniffer Protocols Analog Inputs Max. XScopes 1.3 Specifications Oscilloscope Logic Analyzer General Xprotolab AWG User’s Manual Microcontroller Display Type Display Size Display Life Time Device size Weight Interfaces Battery Active current1 Sleep current Logic Inputs Logic Input levels Input Pull Max. XScopes User’s Manual 1.2 Xprotolab Portable and Xminilab Portable Overview MENU / Power button K3 Input Coupling Switch Analog Inputs Digital Inputs K2 Arbitrary Waveform ON USB Port / Device Charging K1 External Trigger OFF Curve Tracer Switch Figure 7: Xprotolab Portable Curve Tracer Switch USB Port / Device Charging External Trigger Arbitrary Waveform Digital Inputs Analog Inputs MENU / Power button K1 K2 Input Coupling Switch K3 Figure 8: Xminilab Portable 1.2. General Overview 1.1 Xprotolab & Xminilab Pin Description K1 K2 K3 K4 K1 Figure 4: Front and Top Signals K2 K3 K4 Figure 3: Xminilab HW 2.1 & 2.2 Front Signals K1 K2 K3 K4 Figure 5: Back Signals Figure 6: Xminilab HW 2.3 Front Signals Name Description Comment +5V -5V +5V Input voltage -5V Output voltage GND Ground +3.3V Logic 0 Logic 1 Logic 2 Logic 3 Logic 4 Logic 5 Logic 6 Logic 7 EXT. 34 7.2 To send a BMP screen capture to Linux. 34 7.1 To send a BMP screen capture to a PC. XScopes User’s Manual 3.1 Input Selection. XScopes User’s Manual 2.3.3 Trigger Hold. 7 1.2 Xprotolab Portable and Xminilab Portable Overview. 7 1.1 Xprotolab & Xminilab Pin Description. ![]() XScopes User’s Manual TABLE OF CONTENTS 1. Conventions XScope: Xprotolab, Xminilab, Xprotolab Portable or Xminilab Portable. The features documented in this manual are for units with firmware version 2.40+. However, for a full understanding of the operation of the XScopes, the user should be familiar with the operation of a regular oscilloscope. XScopes User’s Manual About this manual This manual targets both novice and advanced users, providing a full resource for everyone. Protocol Sniffer: SPI, I C, UART Advanced Triggering System: Normal / Single / Auto / 2 Free, with many trigger modes adjustable trigger level, and ability to view signals prior to the trigger. Arbitrary Waveform Generator with advanced sweep options on all the wave parameters. 34211 XScopes User’s Manual Main Features: Mixed Signal Oscilloscope: Simultaneous sampling of 2 analog and 8 digital signals. Gabotronics PO BOX 110332 Lakewood Rch, FL.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |